Smart Move® is in rotating mode but not rotating:
- Possibly missing 24V dc power – check for power.
- Possibly missing DMX signal – check for DMX.
- Check that DMX level is at 0 on channels 2 and 3. Channel 1 controls speed and rotation.
Smart Move® won't rotate without DMX signal:
- The unit can be set for fixed rotational mode by setting the rotary switches at 700 – reset the switch to the proper address, then use the second and third rotary switches to choose your programmed effect.
Smart Move® is not indexing properly:
- Make sure channel 3 is at 0, channel 2 is above 0 to set the speed of movement. This allows channel 1 to set the indexed position.
- The homing sensor circuit has failed. Visually inspect rear gobo holder for missing magnetic sensor. Consult Apollo.
Gobo is not firmly held by retaining ring:
- The retaining ring may have been inserted backwards. Remember, place the flat side towards steel gobos, shouldered side towards glass gobos.
Motor turns, but gobo does not:
- Check for loose or broken drive belt.
- Set screw in drive pulley may be loose.
- For double rotators, check that the two steel gobos have not become tangled together.